全自动Dielectric Loss Tester-扬州达瑞

Online Partial Discharge Tester Also Known as Online Partial Discharge Detection Instrument

Published: 2026-09-02

Views: 2922

Category: Cable Fault Tester

Product Description

Online Partial Discharge Tester

The online partial discharge tester (also known as online partial discharge detection instrument or partial discharge online monitoring system) is a professional instrument that performs real-time monitoring and diagnosis of the internal insulation condition of electrical equipment while it remains energized and in operation. It is one of the core tools for the power system's transition from "periodic maintenance" to "condition-based maintenance."

What is Partial Discharge

Partial Discharge (PD) refers to a non-penetrating discharge phenomenon occurring in localized areas of an insulation system. When insulation materials gradually deteriorate due to thermal aging, electrical aging, or environmental factors, the local electric field strength may exceed the insulation withstand level, resulting in discharge. In the early stages, partial discharge often has no obvious external manifestations, making it difficult to detect through traditional inspection methods. However, prolonged continuous discharge will continuously erode the insulation structure and may eventually lead to phase-to-phase short circuits or ground faults.

Main Detection Technologies

Online partial discharge testers typically employ a combination of multiple detection technologies, enhancing monitoring accuracy and reliability through signal complementarity:

Table

Download as Table

Export as Image

Detection Method Principle Features

Ultra-High Frequency Method (UHF) Captures electromagnetic wave signals in the 300MHz~3GHz frequency band Strong anti-interference capability, high sensitivity, suitable for detecting internal discharges

Acoustic Emission Method (AE) Collects mechanical vibration signals of 20kHz~200kHz generated by discharge Good detection effect for surface discharges and corona discharges, resistant to electromagnetic interference

Transient Earth Voltage Method (TEV) Monitors millivolt-level transient voltages on the cabinet shell Easy installation, no power outage required, suitable for switchgear

High-Frequency Current Transformer Method (HFCT) Detects pulse currents on the grounding wire through high-frequency current transformers Non-invasive installation, applicable to cables, transformers, etc.

System Architecture

The online partial discharge monitoring system typically adopts a four-layer architecture design of "sensing layer—transmission layer—analysis layer—application layer":

Sensing layer: Deploys composite sensor arrays (UHF, AE, TEV, HFCT, etc.), using magnetic or rail-type non-invasive installation without altering the electrical characteristics of the equipment

Transmission layer: Supports multiple communication methods such as RS485, Ethernet, LoRa, and 4G/5G, ensuring stable data transmission in complex electromagnetic environments

Analysis layer: Equipped with a discharge pattern recognition engine based on deep learning, automatically distinguishing partial discharges from corona interference, switching operation noise, etc.

Application layer: Through the monitoring platform, it achieves equipment health index assessment, graded alarms, trend prediction, and remote operation and maintenance management, supporting both web and mobile viewing

Key Technical Parameters (Using a Typical Product as an Example)

Taking TBEA's PDP-SMART portable intelligent partial discharge online detection system as an example:

Table

Download as Table

Export as Image

Parameter Item Technical Specification

Detection Channels 3-channel synchronous measurement (single channel optional)

Detection Frequency Band 100kHz~100MHz

Detection Range 1pC~20nC (or equivalent mV value)

Sampling Rate 200MS/s

Detection Sensitivity ≤0.5pC (under laboratory conditions)

Inter-channel Synchronization Time ≤1ns

PD Location Accuracy ≤1 meter

Phase Accuracy ≤0.1°

Operating Ambient Temperature -20℃~+50℃

Applicable Equipment

Online partial discharge testers are suitable for insulation condition monitoring of various high-voltage electrical equipment:

Power transformers: Monitoring the insulation condition of windings and bushings

GIS/GIL: Gas-insulated switchgear and gas-insulated lines

Power cables: Live detection of 66~500kV cable lines

Switchgear: Real-time monitoring of complete distribution equipment

Generators/Motors: Insulation monitoring of stator windings

Instrument transformers, reactors, bushings, etc.

Common Products and Brands

Table

Download as Table

Export as Image

Brand/Product Type Features

OMICRON MONTESTO 200 Mobile temporary online monitoring IP65 protection, plug-and-play, supports remote access and email alerts

OMICRON UHF 800 Ultra-high frequency partial discharge measurement system 100~2000MHz, supports multi-channel synchronous measurement

Megger ICMmonitor Permanent online monitoring Integrated spectrum analyzer + acoustic detection + PD monitoring in one

TBEA PDP-SMART Portable intelligent detection system Strong edge computing capability, suitable for 66~500kV cables

Fankester MEJFD-1000 Online partial discharge detector Maximum sampling rate of 20M, suitable for transformers, cables, etc.

Implementation Standards

GB/T 7354 "Partial Discharge Measurements"

DL/T 417 "Guide for On-site Partial Discharge Measurements of Power Equipment"

DL/T 1430 "Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards"

GB/T 16927 "High-Voltage Test Techniques" series of standards

Selection Key Points

Detection technology combination: Select appropriate sensor combinations based on the type of equipment under test. For switchgear, prioritize TEV+UHF; for transformers, prioritize UHF+AE+HFCT

Monitoring method: Permanent online monitoring (fixed installation) vs. temporary online monitoring (portable). The former is suitable for long-term monitoring of critical equipment, while the latter is suitable for inspections and fault troubleshooting

Sensor performance: Focus on frequency response range, sensitivity, and signal-to-noise ratio

Communication method: Choose wired (RS485/Ethernet/fiber optic) or wireless (LoRa/4G/5G) solutions based on site conditions

Software features: Whether it supports PRPD spectrum analysis, trend prediction, automatic alarms, and remote access

Combined with the insulation resistance tester you previously learned about, the two complement each other in electrical equipment testing—the insulation resistance tester is used for offline detection of insulation resistance values, while the online partial discharge tester is used for real-time monitoring of early signs of insulation deterioration during energized operation. If you have a specific application scenario (such as transformers, switchgear, or cables), you can let me know, and I can help you further refine the selection plan.




WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us